{"product_id":"straight-multi-unit-key","title":"Straight Multi-Unit Key For General Multi-Unit","description":"\u003ch2\u003eStraight driver for seating\/torquing multi-unit abutments \u0026amp; prosthetic screws with precise fit\u003c\/h2\u003e\n\u003cp data-start=\"172\" data-end=\"680\"\u003eThe \u003cstrong data-start=\"176\" data-end=\"210\"\u003eSurcam Straight Multi-Unit Key\u003c\/strong\u003e is a precision driver for \u003cstrong data-start=\"237\" data-end=\"267\"\u003egeneral Multi-Unit systems\u003c\/strong\u003e, engineered to \u003cstrong data-start=\"283\" data-end=\"345\"\u003eseat and torque multi-unit abutments and prosthetic screws\u003c\/strong\u003e with a stable, wobble-free fit. Its straight, slim shank improves access in posterior regions and limited interocclusal space, helping you deliver \u003cstrong data-start=\"493\" data-end=\"531\"\u003epassive, screw-retained frameworks\u003c\/strong\u003e with confidence. The key interfaces with your \u003cstrong data-start=\"578\" data-end=\"612\"\u003edriver handle or torque device\u003c\/strong\u003e per system IFU and is \u003cstrong data-start=\"635\" data-end=\"651\"\u003eautoclavable\u003c\/strong\u003e for routine clinical re-use.\u003c\/p\u003e\n\u003chr data-start=\"682\" data-end=\"685\"\u003e\n\u003ch2 data-start=\"687\" data-end=\"698\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"699\" data-end=\"1082\"\u003e\n\u003cli data-start=\"699\" data-end=\"779\"\u003e\n\u003cp data-start=\"701\" data-end=\"779\"\u003e\u003cstrong data-start=\"701\" data-end=\"724\"\u003eAccurate engagement\u003c\/strong\u003e — Crisp fit minimizes cam-out and screw head damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"780\" data-end=\"858\"\u003e\n\u003cp data-start=\"782\" data-end=\"858\"\u003e\u003cstrong data-start=\"782\" data-end=\"806\"\u003eChairside efficiency\u003c\/strong\u003e — Smooth pickup\/removal of Multi-Unit components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"859\" data-end=\"935\"\u003e\n\u003cp data-start=\"861\" data-end=\"935\"\u003e\u003cstrong data-start=\"861\" data-end=\"887\"\u003eAccess in tight spaces\u003c\/strong\u003e — Straight, slim profile for posterior sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"936\" data-end=\"1014\"\u003e\n\u003cp data-start=\"938\" data-end=\"1014\"\u003e\u003cstrong data-start=\"938\" data-end=\"966\"\u003eReliable torque transfer\u003c\/strong\u003e — Supports consistent seating per system IFU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1015\" data-end=\"1082\"\u003e\n\u003cp data-start=\"1017\" data-end=\"1082\"\u003e\u003cstrong data-start=\"1017\" data-end=\"1033\"\u003eAutoclavable\u003c\/strong\u003e — Built for daily clinical sterilization cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1084\" data-end=\"1087\"\u003e\n\u003ch2 data-start=\"1089\" data-end=\"1107\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1108\" data-end=\"1489\"\u003e\n\u003cli data-start=\"1108\" data-end=\"1184\"\u003e\n\u003cp data-start=\"1110\" data-end=\"1184\"\u003e\u003cstrong data-start=\"1110\" data-end=\"1119\"\u003eType:\u003c\/strong\u003e Straight \u003cstrong data-start=\"1129\" data-end=\"1154\"\u003eMulti-Unit driver\/key\u003c\/strong\u003e (general Multi-Unit system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1185\" data-end=\"1292\"\u003e\n\u003cp data-start=\"1187\" data-end=\"1292\"\u003e\u003cstrong data-start=\"1187\" data-end=\"1201\"\u003eUse Cases:\u003c\/strong\u003e Seating\/torquing \u003cstrong data-start=\"1219\" data-end=\"1273\"\u003eMulti-Unit abutments, prosthetic screws, cylinders\u003c\/strong\u003e (per system IFU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1293\" data-end=\"1346\"\u003e\n\u003cp data-start=\"1295\" data-end=\"1346\"\u003e\u003cstrong data-start=\"1295\" data-end=\"1313\"\u003ePack Contents:\u003c\/strong\u003e \u003cstrong data-start=\"1314\" data-end=\"1344\"\u003e1× Straight Multi-Unit Key\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1347\" data-end=\"1489\"\u003e\n\u003cp data-start=\"1349\" data-end=\"1489\"\u003e\u003cstrong data-start=\"1349\" data-end=\"1367\"\u003eCompatibility:\u003c\/strong\u003e \u003cstrong data-start=\"1368\" data-end=\"1404\"\u003eSurcam General Multi-Unit system\u003c\/strong\u003e and other \u003cstrong data-start=\"1415\" data-end=\"1451\"\u003ecompatible Multi-Unit interfaces\u003c\/strong\u003e (verify geometry and size before use)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1491\" data-end=\"1494\"\u003e\n\u003ch2 data-start=\"1496\" data-end=\"1513\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1514\" data-end=\"1867\"\u003e\n\u003cli data-start=\"1514\" data-end=\"1593\"\u003e\n\u003cp data-start=\"1516\" data-end=\"1593\"\u003e\u003cstrong data-start=\"1516\" data-end=\"1527\"\u003eTorque:\u003c\/strong\u003e Apply values specified by the \u003cstrong data-start=\"1558\" data-end=\"1591\"\u003eimplant\/Multi-Unit system IFU\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1594\" data-end=\"1674\"\u003e\n\u003cp data-start=\"1596\" data-end=\"1674\"\u003e\u003cstrong data-start=\"1596\" data-end=\"1614\"\u003eSterilization:\u003c\/strong\u003e \u003cstrong data-start=\"1615\" data-end=\"1628\"\u003eAutoclave\u003c\/strong\u003e according to clinic protocol and device IFU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1675\" data-end=\"1756\"\u003e\n\u003cp data-start=\"1677\" data-end=\"1756\"\u003e\u003cstrong data-start=\"1677\" data-end=\"1691\"\u003eTechnique:\u003c\/strong\u003e Ensure \u003cstrong data-start=\"1699\" data-end=\"1735\"\u003efull seating and axial alignment\u003c\/strong\u003e prior to torqueing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1757\" data-end=\"1867\"\u003e\n\u003cp data-start=\"1759\" data-end=\"1867\"\u003e\u003cstrong data-start=\"1759\" data-end=\"1769\"\u003eNotes:\u003c\/strong\u003e Always verify \u003cstrong data-start=\"1784\" data-end=\"1815\"\u003edriver interface size\/shape\u003c\/strong\u003e with the component manufacturer before clinical use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1869\" data-end=\"1872\"\u003e\n\u003ch2 data-start=\"1874\" data-end=\"1903\"\u003eWhy Choose Surcam Drivers?\u003c\/h2\u003e\n\u003cul data-start=\"1904\" data-end=\"2079\"\u003e\n\u003cli data-start=\"1904\" data-end=\"1967\"\u003e\n\u003cp data-start=\"1906\" data-end=\"1967\"\u003eConsistent \u003cstrong data-start=\"1917\" data-end=\"1933\"\u003efit and feel\u003c\/strong\u003e for predictable torque delivery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1968\" data-end=\"2016\"\u003e\n\u003cp data-start=\"1970\" data-end=\"2016\"\u003eHelps \u003cstrong data-start=\"1976\" data-end=\"2002\"\u003ereduce stripped screws\u003c\/strong\u003e and remakes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2017\" data-end=\"2079\"\u003e\n\u003cp data-start=\"2019\" data-end=\"2079\"\u003eDesigned for \u003cstrong data-start=\"2032\" data-end=\"2054\"\u003edaily clinical use\u003c\/strong\u003e and repeat sterilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2081\" data-end=\"2084\"\u003e\n\u003ch2 data-start=\"1874\" data-end=\"1903\"\u003eSurcam Drivers FAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2094\" data-end=\"2138\"\u003eWhich Multi-Unit systems are compatible?\u003c\/h3\u003e\n\u003cp data-start=\"2139\" data-end=\"2313\"\u003eGeneral \u003cstrong data-start=\"2147\" data-end=\"2172\"\u003eMulti-Unit interfaces\u003c\/strong\u003e that match this driver’s geometry. Always \u003cstrong data-start=\"2215\" data-end=\"2243\"\u003everify driver size\/shape\u003c\/strong\u003e against your abutment\/screw manufacturer’s specifications before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2315\" data-end=\"2371\"\u003eCan I use this key with angled Multi-Unit abutments?\u003c\/h3\u003e\n\u003cp data-start=\"2372\" data-end=\"2519\"\u003eYes—if the \u003cstrong data-start=\"2383\" data-end=\"2417\"\u003einterface geometry is the same\u003c\/strong\u003e. Confirm fit on the \u003cstrong data-start=\"2438\" data-end=\"2490\"\u003especific angled or straight Multi-Unit component\u003c\/strong\u003e prior to clinical torqueing.\u003c\/p\u003e\n\u003ch3 data-start=\"2521\" data-end=\"2552\"\u003eWhat torque should I apply?\u003c\/h3\u003e\n\u003cp data-start=\"2553\" data-end=\"2693\"\u003eFollow the \u003cstrong data-start=\"2564\" data-end=\"2597\"\u003eimplant\/Multi-Unit system IFU\u003c\/strong\u003e for abutment and prosthetic screw torque values. \u003cstrong data-start=\"2647\" data-end=\"2664\"\u003eDo not exceed\u003c\/strong\u003e manufacturer specifications.\u003c\/p\u003e\n\u003ch3 data-start=\"2695\" data-end=\"2738\"\u003eHow do I avoid cam-out or screw damage?\u003c\/h3\u003e\n\u003cp data-start=\"2739\" data-end=\"2878\"\u003eEnsure \u003cstrong data-start=\"2746\" data-end=\"2782\"\u003efull seating and axial alignment\u003c\/strong\u003e, use a \u003cstrong data-start=\"2790\" data-end=\"2818\"\u003ecalibrated torque device\u003c\/strong\u003e, and maintain clean, undamaged driver tips and screw heads.\u003c\/p\u003e\n\u003ch3 data-start=\"2880\" data-end=\"2915\"\u003eHow should I sterilize the key?\u003c\/h3\u003e\n\u003cp data-start=\"2916\" data-end=\"3022\"\u003eProcess via \u003cstrong data-start=\"2928\" data-end=\"2941\"\u003eautoclave\u003c\/strong\u003e per your clinic’s sterilization protocol and the device IFU before each patient.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"en\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which Multi-Unit systems are compatible?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"General Multi-Unit interfaces that match this driver’s geometry. Always verify driver size and interface shape against your abutment and screw manufacturer’s specifications before use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can this key be used with angled Multi-Unit abutments?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, provided the interface geometry is identical. Confirm fit on the specific angled or straight Multi-Unit component before clinical torqueing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What torque should be applied?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use the torque values specified by the implant\/Multi-Unit system instructions for use (IFU) for both abutment and prosthetic screws. Do not exceed manufacturer limits.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can cam-out or screw damage be prevented?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Ensure full seating and axial alignment, use a calibrated torque device, and keep driver tips and screw heads clean and undamaged.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How should the key be sterilized?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Sterilize via autoclave in accordance with your clinic’s protocol and the device’s instructions for use prior to each patient.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Surcamdental","offers":[{"title":"Default Title","offer_id":49754545160469,"sku":"TEM-130016","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1302\/3253\/files\/TEM-130016.1_Shopify.jpg?v=1770031915","url":"https:\/\/surcamdental.us\/products\/straight-multi-unit-key","provider":"Surcam Dental US","version":"1.0","type":"link"}