{"product_id":"screwdriver-implant-key-2-42","title":"Screwdriver 2.42 mm Implant Key","description":"\u003ch2 data-start=\"34\" data-end=\"129\"\u003eInternal Hex 2.42 driver for seating\/removing abutments \u0026amp; prosthetic screws with precise fit\u003c\/h2\u003e\n\u003cp data-start=\"155\" data-end=\"548\"\u003eThe \u003cstrong data-start=\"159\" data-end=\"201\"\u003eSurcam Screwdriver 2.42 mm Implant Key\u003c\/strong\u003e is engineered for \u003cstrong data-start=\"220\" data-end=\"244\"\u003eInternal Hex 2.42 mm\u003c\/strong\u003e implant platforms, providing a \u003cstrong data-start=\"276\" data-end=\"304\"\u003eprecise, wobble-free fit\u003c\/strong\u003e to seat or remove abutments, healing caps, cover screws, and prosthetic screws according to system IFU. A tight interface helps \u003cstrong data-start=\"433\" data-end=\"473\"\u003ereduce cam-out and screw head damage\u003c\/strong\u003e, supporting predictable torque delivery and efficient chairside workflows.\u003c\/p\u003e\n\u003chr data-start=\"550\" data-end=\"553\"\u003e\n\u003ch2 data-start=\"555\" data-end=\"566\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"567\" data-end=\"1050\"\u003e\n\u003cli data-start=\"567\" data-end=\"671\"\u003e\n\u003cp data-start=\"569\" data-end=\"671\"\u003e\u003cstrong data-start=\"569\" data-end=\"592\"\u003eAccurate engagement\u003c\/strong\u003e - Crisp fit on \u003cstrong data-start=\"608\" data-end=\"629\"\u003eInternal Hex 2.42\u003c\/strong\u003e platforms for reliable torque transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"672\" data-end=\"776\"\u003e\n\u003cp data-start=\"674\" data-end=\"776\"\u003e\u003cstrong data-start=\"674\" data-end=\"697\"\u003eProtects components\u003c\/strong\u003e - Minimizes cam-out and rounding of screw heads during tightening\/loosening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"777\" data-end=\"874\"\u003e\n\u003cp data-start=\"779\" data-end=\"874\"\u003e\u003cstrong data-start=\"779\" data-end=\"803\"\u003eChairside efficiency\u003c\/strong\u003e - Speeds up placement and retrieval of common prosthetic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"875\" data-end=\"963\"\u003e\n\u003cp data-start=\"877\" data-end=\"963\"\u003e\u003cstrong data-start=\"877\" data-end=\"900\"\u003eSterilization-ready\u003c\/strong\u003e - Designed for routine autoclave cycles per clinic protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1050\"\u003e\n\u003cp data-start=\"966\" data-end=\"1050\"\u003e\u003cstrong data-start=\"966\" data-end=\"989\"\u003eBroad ecosystem fit\u003c\/strong\u003e - Compatible with leading IH 2.42 systems (verify platform).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1052\" data-end=\"1055\"\u003e\n\u003ch2 data-start=\"1057\" data-end=\"1075\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1076\" data-end=\"1543\"\u003e\n\u003cli data-start=\"1076\" data-end=\"1130\"\u003e\n\u003cp data-start=\"1078\" data-end=\"1130\"\u003e\u003cstrong data-start=\"1078\" data-end=\"1103\"\u003eInterface \/ Platform:\u003c\/strong\u003e \u003cstrong data-start=\"1104\" data-end=\"1128\"\u003eInternal Hex 2.42 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1131\" data-end=\"1244\"\u003e\n\u003cp data-start=\"1133\" data-end=\"1244\"\u003e\u003cstrong data-start=\"1133\" data-end=\"1147\"\u003eUse Cases:\u003c\/strong\u003e Seating\/removing \u003cstrong data-start=\"1165\" data-end=\"1225\"\u003eabutments, healing caps, cover screws, prosthetic screws\u003c\/strong\u003e (per system IFU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1245\" data-end=\"1372\"\u003e\n\u003cp data-start=\"1247\" data-end=\"1372\"\u003e\u003cstrong data-start=\"1247\" data-end=\"1265\"\u003eHandle\/Driver:\u003c\/strong\u003e Works with standard clinical driver workflow (follow your system’s recommended handle and torque device)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1373\" data-end=\"1543\"\u003e\n\u003cp data-start=\"1375\" data-end=\"1543\"\u003e\u003cstrong data-start=\"1375\" data-end=\"1399\"\u003eBrand Compatibility:\u003c\/strong\u003e Common \u003cstrong data-start=\"1407\" data-end=\"1418\"\u003eIH 2.42\u003c\/strong\u003e families including \u003cstrong data-start=\"1438\" data-end=\"1452\"\u003eAlpha Bio®\u003c\/strong\u003e, \u003cstrong data-start=\"1454\" data-end=\"1465\"\u003eZimmer®\u003c\/strong\u003e, \u003cstrong data-start=\"1467\" data-end=\"1475\"\u003eMIS®\u003c\/strong\u003e, \u003cstrong data-start=\"1477\" data-end=\"1486\"\u003eAdin®\u003c\/strong\u003e, \u003cstrong data-start=\"1488\" data-end=\"1507\"\u003eImplant Direct®\u003c\/strong\u003e, \u003cstrong data-start=\"1509\" data-end=\"1523\"\u003eAB Dental®\u003c\/strong\u003e (confirm interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1545\" data-end=\"1548\"\u003e\n\u003ch2 data-start=\"1550\" data-end=\"1567\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1568\" data-end=\"1886\"\u003e\n\u003cli data-start=\"1568\" data-end=\"1636\"\u003e\n\u003cp data-start=\"1570\" data-end=\"1636\"\u003e\u003cstrong data-start=\"1570\" data-end=\"1581\"\u003eTorque:\u003c\/strong\u003e Apply values specified by the \u003cstrong data-start=\"1612\" data-end=\"1634\"\u003eimplant system IFU\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1637\" data-end=\"1715\"\u003e\n\u003cp data-start=\"1639\" data-end=\"1715\"\u003e\u003cstrong data-start=\"1639\" data-end=\"1657\"\u003eSterilization:\u003c\/strong\u003e Autoclave per clinic protocol and manufacturer guidance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1716\" data-end=\"1810\"\u003e\n\u003cp data-start=\"1718\" data-end=\"1810\"\u003e\u003cstrong data-start=\"1718\" data-end=\"1734\"\u003eIndications:\u003c\/strong\u003e Chairside placement\/removal of compatible components on IH 2.42 platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1811\" data-end=\"1886\"\u003e\n\u003cp data-start=\"1813\" data-end=\"1886\"\u003e\u003cstrong data-start=\"1813\" data-end=\"1823\"\u003eNotes:\u003c\/strong\u003e Always verify platform dimensions and seating before torqueing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1888\" data-end=\"1891\"\u003e\n\u003ch2 data-start=\"1893\" data-end=\"1922\"\u003eWhy Choose Surcam Drivers?\u003c\/h2\u003e\n\u003cul data-start=\"1923\" data-end=\"2122\"\u003e\n\u003cli data-start=\"1923\" data-end=\"1984\"\u003e\n\u003cp data-start=\"1925\" data-end=\"1984\"\u003eConsistent \u003cstrong data-start=\"1936\" data-end=\"1952\"\u003efit and feel\u003c\/strong\u003e for confident torque delivery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1985\" data-end=\"2053\"\u003e\n\u003cp data-start=\"1987\" data-end=\"2053\"\u003eStreamlined workflows with \u003cstrong data-start=\"2014\" data-end=\"2051\"\u003efewer remakes and stripped screws\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2054\" data-end=\"2122\"\u003e\n\u003cp data-start=\"2056\" data-end=\"2122\"\u003eBuilt for \u003cstrong data-start=\"2066\" data-end=\"2088\"\u003edaily clinical use\u003c\/strong\u003e and repeated sterilization cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2124\" data-end=\"2127\"\u003e\n\u003ch2 data-start=\"1893\" data-end=\"1922\"\u003eDrivers FAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2137\" data-end=\"2178\"\u003eWhich implant systems are compatible?\u003c\/h3\u003e\n\u003cp data-start=\"2179\" data-end=\"2357\"\u003eInternal Hex \u003cstrong data-start=\"2192\" data-end=\"2203\"\u003e2.42 mm\u003c\/strong\u003e platforms commonly used by \u003cstrong data-start=\"2231\" data-end=\"2296\"\u003eAlpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, AB Dental®\u003c\/strong\u003e. Always verify platform dimensions and interface before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2359\" data-end=\"2417\"\u003eWhat components can I seat or remove with this driver?\u003c\/h3\u003e\n\u003cp data-start=\"2418\" data-end=\"2558\"\u003eAbutments, healing caps, cover screws, and prosthetic screws \u003cstrong data-start=\"2479\" data-end=\"2514\"\u003edesigned for IH 2.42 interfaces\u003c\/strong\u003e, following the specific implant system IFU.\u003c\/p\u003e\n\u003ch3 data-start=\"2560\" data-end=\"2589\"\u003eWhat torque should I use?\u003c\/h3\u003e\n\u003cp data-start=\"2590\" data-end=\"2716\"\u003eUse the \u003cstrong data-start=\"2598\" data-end=\"2633\"\u003emanufacturer-recommended torque\u003c\/strong\u003e for the component you are placing; do not exceed values in the implant system IFU.\u003c\/p\u003e\n\u003ch3 data-start=\"2718\" data-end=\"2756\"\u003eHow should I sterilize the driver?\u003c\/h3\u003e\n\u003cp data-start=\"2757\" data-end=\"2869\"\u003eProcess via \u003cstrong data-start=\"2769\" data-end=\"2782\"\u003eautoclave\u003c\/strong\u003e according to your clinic’s sterilization protocol and the device instructions for use.\u003c\/p\u003e\n\u003ch3 data-start=\"2871\" data-end=\"2914\"\u003eHow do I avoid cam-out or screw damage?\u003c\/h3\u003e\n\u003cp data-start=\"2915\" data-end=\"3029\"\u003eEnsure \u003cstrong data-start=\"2922\" data-end=\"2958\"\u003efull seating and axial alignment\u003c\/strong\u003e before torqueing; use calibrated torque devices and follow IFU limits.\u003c\/p\u003e\n\u003cp data-start=\"2915\" data-end=\"3029\"\u003e* Trademark note: Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, and AB Dental® are registered trademarks of their respective owners. References are for compatibility\/comparison only.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"en\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which implant systems are compatible?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Internal Hex 2.42 mm platforms commonly used by Alpha Bio®, Zimmer®, MIS®, Adin®, Implant Direct®, and AB Dental®. Always verify platform dimensions and interface before clinical use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What components can be seated or removed with this driver?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Abutments, healing caps, cover screws, and prosthetic screws designed for IH 2.42 interfaces, following the implant system’s instructions for use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What torque should be applied?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use only the torque values recommended by the implant system IFU for the specific component. Do not exceed manufacturer specifications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How should the driver be sterilized?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Sterilize via autoclave in accordance with your clinic’s protocol and the device’s instructions for use before each patient.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can cam-out or screw damage be prevented?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Ensure full seating and axial alignment prior to torqueing, use calibrated torque drivers, and adhere to the IFU torque limits.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Surcamdental","offers":[{"title":"12mm","offer_id":49754549190933,"sku":"KSH-1224","price":50.0,"currency_code":"USD","in_stock":true},{"title":"18mm","offer_id":49754549223701,"sku":"KSH-1824","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1302\/3253\/files\/KSH-1224.1_Shopify.jpg?v=1770032154","url":"https:\/\/surcamdental.us\/products\/screwdriver-implant-key-2-42","provider":"Surcam Dental US","version":"1.0","type":"link"}