{"product_id":"angular-narrow-multi-unit-np-3-5-18-30","title":"Angular Narrow Multi-Unit","description":"\u003ch2\u003eNarrow-profile angled Multi-Unit for NP 3.5 - path alignment, low profile \u0026amp; screw-retained workflow\u003c\/h2\u003e\n\u003cp data-start=\"156\" data-end=\"926\"\u003eThe \u003cstrong data-start=\"160\" data-end=\"196\"\u003eSurcam Angular Narrow Multi-Unit\u003c\/strong\u003e is a \u003cstrong data-start=\"202\" data-end=\"247\"\u003enarrow-profile, conical-connection NP 3.5\u003c\/strong\u003e abutment engineered for \u003cstrong data-start=\"272\" data-end=\"301\"\u003escrew-retained prostheses\u003c\/strong\u003e when implants are \u003cstrong data-start=\"320\" data-end=\"330\"\u003etilted\u003c\/strong\u003e or space is limited. The slim transmucosal profile improves cleansability and soft-tissue adaptation in tight embrasures, while angled options correct implant divergence to establish a common path of insertion for passive frameworks. Precision-machined from \u003cstrong data-start=\"589\" data-end=\"621\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e, it supports immediate provisionalization (case-dependent) and predictable full-arch or segmental restorations.\u003cbr data-start=\"733\" data-end=\"736\"\u003e\u003cstrong data-start=\"736\" data-end=\"749\"\u003eIncludes:\u003c\/strong\u003e 1× Angular Narrow Multi-Unit abutment, 1× Prosthetic Screw.\u003cbr data-start=\"809\" data-end=\"812\"\u003e\u003cstrong data-start=\"812\" data-end=\"830\"\u003eCompatibility:\u003c\/strong\u003e \u003cstrong data-start=\"831\" data-end=\"860\"\u003eNP 3.5 conical connection\u003c\/strong\u003e (e.g., Nobel Active® NP) — verify platform\/interface before use.*\u003c\/p\u003e\n\u003chr data-start=\"928\" data-end=\"931\"\u003e\n\u003ch2 data-start=\"933\" data-end=\"944\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-start=\"945\" data-end=\"1506\"\u003e\n\u003cli data-start=\"945\" data-end=\"1055\"\u003e\n\u003cp data-start=\"947\" data-end=\"1055\"\u003e\u003cstrong data-start=\"947\" data-end=\"972\"\u003eDivergence correction\u003c\/strong\u003e — Angled options align the restorative axis for passive, screw-retained seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1056\" data-end=\"1154\"\u003e\n\u003cp data-start=\"1058\" data-end=\"1154\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1089\"\u003eNarrow transmucosal profile\u003c\/strong\u003e — Better emergence and hygiene in tight spaces or thin ridges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1155\" data-end=\"1249\"\u003e\n\u003cp data-start=\"1157\" data-end=\"1249\"\u003e\u003cstrong data-start=\"1157\" data-end=\"1177\"\u003eLow-profile head\u003c\/strong\u003e — Improves tongue space and cleansability under full-arch frameworks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1250\" data-end=\"1332\"\u003e\n\u003cp data-start=\"1252\" data-end=\"1332\"\u003e\u003cstrong data-start=\"1252\" data-end=\"1270\"\u003eRetrievability\u003c\/strong\u003e — Screw-retained access simplifies maintenance and hygiene.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1333\" data-end=\"1418\"\u003e\n\u003cp data-start=\"1335\" data-end=\"1418\"\u003e\u003cstrong data-start=\"1335\" data-end=\"1358\"\u003eMaterial confidence\u003c\/strong\u003e — \u003cstrong data-start=\"1361\" data-end=\"1382\"\u003eTi-6Al-4V Grade 5\u003c\/strong\u003e durability with precise indexing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1419\" data-end=\"1506\"\u003e\n\u003cp data-start=\"1421\" data-end=\"1506\"\u003e\u003cstrong data-start=\"1421\" data-end=\"1444\"\u003eImmediate workflows\u003c\/strong\u003e — Supports same-day provisionals when torque\/occlusion allow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1508\" data-end=\"1511\"\u003e\n\u003ch2 data-start=\"1513\" data-end=\"1531\"\u003eProduct Details\u003c\/h2\u003e\n\u003cul data-start=\"1532\" data-end=\"1895\"\u003e\n\u003cli data-start=\"1532\" data-end=\"1610\"\u003e\n\u003cp data-start=\"1534\" data-end=\"1610\"\u003e\u003cstrong data-start=\"1534\" data-end=\"1560\"\u003ePlatform \/ Connection:\u003c\/strong\u003e \u003cstrong data-start=\"1561\" data-end=\"1571\"\u003eNP 3.5\u003c\/strong\u003e conical connection (narrow platform)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1611\" data-end=\"1773\"\u003e\n\u003cp data-start=\"1613\" data-end=\"1697\"\u003e\u003cstrong data-start=\"1613\" data-end=\"1658\"\u003eAngulations \u0026amp; Cuff (Transmucosal) Heights\u003c\/strong\u003e \u003cem data-start=\"1659\" data-end=\"1694\"\u003e(“Length” = gingival\/cuff height)\u003c\/em\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1700\" data-end=\"1773\"\u003e\n\u003cli data-start=\"1700\" data-end=\"1735\"\u003e\n\u003cp data-start=\"1702\" data-end=\"1735\"\u003e\u003cstrong data-start=\"1702\" data-end=\"1709\"\u003e18°\u003c\/strong\u003e: \u003cstrong data-start=\"1711\" data-end=\"1721\"\u003e2.0 mm\u003c\/strong\u003e, \u003cstrong data-start=\"1723\" data-end=\"1733\"\u003e3.5 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1738\" data-end=\"1773\"\u003e\n\u003cp data-start=\"1740\" data-end=\"1773\"\u003e\u003cstrong data-start=\"1740\" data-end=\"1747\"\u003e30°\u003c\/strong\u003e: \u003cstrong data-start=\"1749\" data-end=\"1759\"\u003e2.7 mm\u003c\/strong\u003e, \u003cstrong data-start=\"1761\" data-end=\"1771\"\u003e3.7 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1774\" data-end=\"1824\"\u003e\n\u003cp data-start=\"1776\" data-end=\"1824\"\u003e\u003cstrong data-start=\"1776\" data-end=\"1789\"\u003eMaterial:\u003c\/strong\u003e \u003cstrong data-start=\"1790\" data-end=\"1822\"\u003eTitanium Grade 5 (Ti-6Al-4V)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1825\" data-end=\"1895\"\u003e\n\u003cp data-start=\"1827\" data-end=\"1895\"\u003e\u003cstrong data-start=\"1827\" data-end=\"1845\"\u003ePack Contents:\u003c\/strong\u003e 1× Angular Narrow Multi-Unit, 1× Prosthetic Screw\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1897\" data-end=\"1900\"\u003e\n\u003ch2 data-start=\"1902\" data-end=\"1919\"\u003eSpecifications\u003c\/h2\u003e\n\u003cul data-start=\"1920\" data-end=\"2376\"\u003e\n\u003cli data-start=\"1920\" data-end=\"2018\"\u003e\n\u003cp data-start=\"1922\" data-end=\"2018\"\u003e\u003cstrong data-start=\"1922\" data-end=\"1938\"\u003eIndications:\u003c\/strong\u003e Screw-retained single, segmental, and full-arch prostheses on NP 3.5 implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2019\" data-end=\"2109\"\u003e\n\u003cp data-start=\"2021\" data-end=\"2109\"\u003e\u003cstrong data-start=\"2021\" data-end=\"2034\"\u003eWorkflow:\u003c\/strong\u003e Supports \u003cstrong data-start=\"2044\" data-end=\"2076\"\u003eimmediate provisionalization\u003c\/strong\u003e when primary stability permits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2110\" data-end=\"2199\"\u003e\n\u003cp data-start=\"2112\" data-end=\"2199\"\u003e\u003cstrong data-start=\"2112\" data-end=\"2123\"\u003eTorque:\u003c\/strong\u003e Seat\/torque per \u003cstrong data-start=\"2140\" data-end=\"2162\"\u003eimplant system IFU\u003c\/strong\u003e; do not exceed manufacturer values\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2200\" data-end=\"2303\"\u003e\n\u003cp data-start=\"2202\" data-end=\"2303\"\u003e\u003cstrong data-start=\"2202\" data-end=\"2218\"\u003eProsthetics:\u003c\/strong\u003e Use compatible multi-unit cylinders, temp cylinders, and screws per system library\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2304\" data-end=\"2376\"\u003e\n\u003cp data-start=\"2306\" data-end=\"2376\"\u003e\u003cstrong data-start=\"2306\" data-end=\"2318\"\u003eHygiene:\u003c\/strong\u003e Narrow, low profile aids plaque control around the collar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2378\" data-end=\"2381\"\u003e\n\u003ch2 data-start=\"2383\" data-end=\"2415\"\u003eWhy Choose Surcam Multi-Unit?\u003c\/h2\u003e\n\u003cul data-start=\"2416\" data-end=\"2620\"\u003e\n\u003cli data-start=\"2416\" data-end=\"2479\"\u003e\n\u003cp data-start=\"2418\" data-end=\"2479\"\u003ePredictable \u003cstrong data-start=\"2430\" data-end=\"2448\"\u003epath alignment\u003c\/strong\u003e on tilted\/divergent implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2480\" data-end=\"2551\"\u003e\n\u003cp data-start=\"2482\" data-end=\"2551\"\u003e\u003cstrong data-start=\"2482\" data-end=\"2500\"\u003eNarrow profile\u003c\/strong\u003e for challenging esthetic zones and limited space\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2552\" data-end=\"2620\"\u003e\n\u003cp data-start=\"2554\" data-end=\"2620\"\u003e\u003cstrong data-start=\"2554\" data-end=\"2569\"\u003eRetrievable\u003c\/strong\u003e screw-retained design for long-term serviceability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2622\" data-end=\"2625\"\u003e\n\u003ch2 data-start=\"2383\" data-end=\"2415\"\u003eSurcam Multi-Unit FAQs\u003c\/h2\u003e\n\u003ch3 data-start=\"2636\" data-end=\"2691\"\u003eWhich platforms is this Multi-Unit compatible with?\u003c\/h3\u003e\n\u003cp data-start=\"2692\" data-end=\"2817\"\u003eNP \u003cstrong data-start=\"2695\" data-end=\"2721\"\u003e3.5 conical-connection\u003c\/strong\u003e platforms (e.g., Nobel Active® NP). Always verify platform dimensions and interface before use.\u003c\/p\u003e\n\u003ch3 data-start=\"2819\" data-end=\"2872\"\u003eWhich angulations and cuff heights are available?\u003c\/h3\u003e\n\u003cp data-start=\"2873\" data-end=\"2976\"\u003e\u003cstrong data-start=\"2873\" data-end=\"2880\"\u003e18°\u003c\/strong\u003e with \u003cstrong data-start=\"2886\" data-end=\"2896\"\u003e2.0 mm\u003c\/strong\u003e or \u003cstrong data-start=\"2900\" data-end=\"2910\"\u003e3.5 mm\u003c\/strong\u003e cuff heights; \u003cstrong data-start=\"2925\" data-end=\"2932\"\u003e30°\u003c\/strong\u003e with \u003cstrong data-start=\"2938\" data-end=\"2948\"\u003e2.7 mm\u003c\/strong\u003e or \u003cstrong data-start=\"2952\" data-end=\"2962\"\u003e3.7 mm\u003c\/strong\u003e cuff heights.\u003c\/p\u003e\n\u003ch3 data-start=\"2978\" data-end=\"3029\"\u003eHow do I choose the right cuff height (length)?\u003c\/h3\u003e\n\u003cp data-start=\"3030\" data-end=\"3233\"\u003eMatch cuff height to \u003cstrong data-start=\"3051\" data-end=\"3072\"\u003emucosal thickness\u003c\/strong\u003e and desired emergence: thinner tissue → \u003cstrong data-start=\"3113\" data-end=\"3124\"\u003eshorter\u003c\/strong\u003e cuff; thicker tissue\/concave emergence → \u003cstrong data-start=\"3166\" data-end=\"3176\"\u003elonger\u003c\/strong\u003e cuff. Confirm clinically (probing) and radiographically.\u003c\/p\u003e\n\u003ch3 data-start=\"3235\" data-end=\"3269\"\u003eWhen should I pick 18° vs 30°?\u003c\/h3\u003e\n\u003cp data-start=\"3270\" data-end=\"3415\"\u003eUse \u003cstrong data-start=\"3274\" data-end=\"3281\"\u003e18°\u003c\/strong\u003e for mild\/moderate divergence; \u003cstrong data-start=\"3312\" data-end=\"3319\"\u003e30°\u003c\/strong\u003e when greater correction is needed to obtain a \u003cstrong data-start=\"3366\" data-end=\"3394\"\u003ecommon path of insertion\u003c\/strong\u003e for passive seating.\u003c\/p\u003e\n\u003ch3 data-start=\"3417\" data-end=\"3460\"\u003eCan this be used for immediate loading?\u003c\/h3\u003e\n\u003cp data-start=\"3461\" data-end=\"3599\"\u003eOften \u003cstrong data-start=\"3467\" data-end=\"3485\"\u003ecase-dependent\u003c\/strong\u003e. Immediate provisionalization requires adequate insertion torque, cross-arch splinting, and controlled occlusion.\u003c\/p\u003e\n\u003ch3 data-start=\"3601\" data-end=\"3667\"\u003eWhat torque should I use for seating and the prosthetic screw?\u003c\/h3\u003e\n\u003cp data-start=\"3668\" data-end=\"3783\"\u003eFollow the \u003cstrong data-start=\"3679\" data-end=\"3703\"\u003eimplant system’s IFU\u003c\/strong\u003e for NP 3.5 multi-unit torque values. Do not exceed manufacturer specifications.\u003c\/p\u003e\n\u003cp data-start=\"3785\" data-end=\"3899\"\u003e* \u003cstrong data-start=\"3788\" data-end=\"3805\"\u003eNobel Active®\u003c\/strong\u003e is a registered trademark of Nobel Biocare. References are for compatibility\/comparison only.\u003c\/p\u003e\n  \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"en\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which platforms is this Multi-Unit compatible with?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"NP 3.5 conical-connection platforms (e.g., Nobel Active NP). Always verify platform dimensions and interface before clinical use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which angulations and cuff heights are available?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Available options: 18° with 2.0 mm or 3.5 mm cuff heights, and 30° with 2.7 mm or 3.7 mm cuff heights.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How do I choose the right cuff height?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Select the cuff (transmucosal) height based on mucosal thickness and the desired emergence profile. Thinner tissue favors shorter cuffs; thicker tissue favors longer cuffs. Confirm clinically and radiographically.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"When should I pick 18° versus 30°?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use 18° for mild to moderate implant divergence and 30° for greater correction to create a common path of insertion for passive, screw-retained seating.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can this Multi-Unit be used for immediate loading?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, case dependent. Immediate provisionalization requires adequate insertion torque, cross-arch splinting, and controlled occlusion per clinical protocol.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What torque should be used for seating and the prosthetic screw?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Follow the implant system’s instructions for use (IFU) for NP 3.5 Multi-Unit torque values and do not exceed manufacturer specifications.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Surcamdental","offers":[{"title":"18° Deg \/ 2.0 mm","offer_id":49754543784213,"sku":"NAMU-130022","price":55.0,"currency_code":"USD","in_stock":true},{"title":"18° Deg \/ 3.5 mm","offer_id":49754543816981,"sku":"NAMU-130023","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 2.7 mm","offer_id":49754543849749,"sku":"NAMU-130024","price":55.0,"currency_code":"USD","in_stock":true},{"title":"30° Deg \/ 3.7 mm","offer_id":49754543882517,"sku":"NAMU-130025","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/1302\/3253\/files\/NAMU-130022.1_Shopify_b91c0b63-f782-4655-97b2-f1046f387c7b.jpg?v=1770031788","url":"https:\/\/surcamdental.us\/products\/angular-narrow-multi-unit-np-3-5-18-30","provider":"Surcam Dental US","version":"1.0","type":"link"}